Deflection Calculation According To EC2 Pdf
2.0 MATLAB CODE FOR SHEAR DESIGN ACCORDING TO EC2. Previous article Two Approaches to the Calculation of Deflection in EC2. Manual Design of Beam and Raft Foundation to Eurocode 2 (free PDF download) Eurocode 2 Ubani Obinna Uzodimma-August 22, 2019 4. In our last post, we considered the analysis of beam and raft foundation of a G+1. Values given in EC2 are indicative and vary according to type of aggregate. Width or calculate the value of cot θ for which VEd = VRd,c and repeat the calculation. Deflection of ECC specimen, V. Li, University of Michigan.
Eurocode 2 (EN1992-1-1) proposes equations for the calculation of crack width, taking into account several parameters, like the concrete and steel strain and reinforcing bar diameters.
According to Eurocode 2, the crack width, wk, can be calculated from the following equation:
wk = sr,max (εsm –εcm)
, where
sr,max: the maximum crack spacing
εsm: the mean strain in the reinforcement under the relevant combination of loads, including the effect of imposed deformations and taking into account the effects of tension stiffening. Only the additional tensile strain beyond the state of zero strain of the concrete at the same level is considered
εcm: the mean strain in the concrete between cracks
- The difference εsm –εcm can be calculated from the following expression:
, where:
σs: the stress in the tension reinforcement assuming a cracked section. For pretensioned members, σs may be replaced by Δσp the stress variation in prestressing tendons from the state of zero strain of the concrete at the same level.
Αe: the ratio Es/Ecm
ρp,eff (As + ξ12 Ap’)/Ac,eff ,where
Ap‘ is the area of pre or post-tensioned tendons within Ac,eff.
Neeya naana shows free download. Vijay tv Shows, Neeya NaanaVijay tv Program Neeya Naana 14th July 2019NeeyaNaana is a Talk Show is a Tamil talk show on the regional television channel Vijay TV of STAR TV network.It brings together polarized sections of the society and allow them to debate on a topic that affects them the most and they share their views, opinions and counter-arguments. The show is currently being hosted by Gopinath, who has been the host since the program began. Every week a topic is chosen and two groups of people representing the extreme ends face each other and discuss on the show. The program deals with the subject both light-heartedly as well as seriously at the same time and often features celebrity guests.
Ac,eff is the effective area of concrete in tension surrounding the reinforcement or prestressing tendons of depth, hc,ef , where hc,ef is the lesser of 2,5(h-d), (h-x)/3 or h/2
, where
ξ: ratio of bond strength of prestressing and reinforcing steel
φs: largest bar diameter of reinforcing steel
φp: equivalent diameter of tendon
kt: a factor dependent on the duration of the load
kt = 0.6 for short term loading
kt = 0.4 for long term loading
- In situations where bonded reinforcement is fixed at reasonably close centers within the tension zone (spacing ≤ 5(c+φ/2), the maximum final crack spacing should be calculated from the following equation:
sr,max = k3c + k1k2k4φ /ρp,effKumpulan font ttf unicode keren.
, where:
φ: he bar diameter. Where a mixture of bar diameters is used in a section, an equivalent diameter, φeq, should be used. For a section with n1 bars of diameter φ1 and n2 bars of diameter φ2, we should use the following equation:
c: the cover to the longitudinal reinforcement
k1: a coefficient which takes account of the bond properties of the bonded reinforcement:
= 0,8 for high bond bars
= 1,6 for bars with an effectively plain surface (e.g. prestressing tendons)
k2: a coefficient which takes account of the distribution of strain:
= 0,5 for bending
= 1,0 for pure tension
For cases of eccentric tension or for local areas, intermediate values of k2 should be used which may be calculated from the equation:
k2 = (ε1 + ε2)/2ε1 (7.13) , where
ε1 is the greater and ε2 is the lesser tensile strain at the boundaries of the section considered, assessed on the basis of a cracked section
Note: The values of k3 and k4 for use in a Country may be found in its National Annex. The recommended values are 3,4 and 0,425 respectively.
Where the spacing of the bonded reinforcement exceeds 5(c+φ/2) or where there is no bonded reinforcement within the tension zone, an upper bound to the crack width should be calculated by assuming a maximum crack spacing:
sr,max = 1,3 (h - x)
Where the angle between the axes of principal stress and the direction of the reinforcement, for members reinforced in two orthogonal directions, is significant (>15°), then the crack spacing sr,max may be calculated from the following equation:
, where:
θ: the angle between the reinforcement in the y direction and the direction of the principal tensile stress
sr,max,y, sr,max,z: the crack spacings calculated in the y and z directions respectively
- For walls subjected to early thermal contraction where the horizontal steel area, As does not fulfil minimum reinforcement requirements and where the bottom of the wall is restrained by a previously cast base, sr,max may be assumed to be equal to 1.3 times the height of the wall.